Mar 21, 2016 · Concrete should be sampled at both ends of the pumpline to determine what, if any, changes in the slump, air content, and other concrete properties occur during pumping. However, the quality of the concrete being placed in the structure can only be …

Learn More

What Is Meant By 'Concrete Slump' & Why Does It Matter

A concrete slump test is a way of finding out the consistency of different concretes. The benefits of performing a slump test are that it shows the workability of the concrete and the ease with which it flows, as well as being an indicator of an improperly mixed batch. Checkout our guide on Concrete Slump Tests – a detailed guide on how to

Learn More

Principle of mix design for pumpable concrete | ACE Update

Sep 23, 2020 · Workability of pumped concrete. The workability of pumped concrete, in general, has an average slump of between 50 mm and 100 mm. A concrete of less than 50 mm slump is impractical for pumping, and slump above 125 mm should be avoided. In mixtures with a high slump, the aggregate will segregate from the mortar and paste and cause choking.

Learn More

What is the slump value for pouring the mass concrete with

Answer: The required slump depends on the pump, hose diameter, and distance, particularly height. Boom pumps with a six inch pump reduced to a four inch discharge tube and hose will handle pea gravel or small coarse aggregate mixes at slightly less than a four inch slump, but that is pushing the

Learn More

Principle of mix design for pumpable concrete

Sep 23, 2020 · The workability of pumped concrete, in general, has an average slump of between 50 mm and 100 mm. A concrete of less than 50 mm slump is impractical for pumping, and slump above 125 mm should be avoided. In mixtures with a high slump, the aggregate will segregate from the mortar and paste and cause choking.

Learn More

Concrete Slipform Construction - Common Questions

Some parameters of the concrete mix (setting time, slump, etc.) should be reviewed, but there is no special concrete required for general slipforming. A typical 'pump mix' with 3 to 4 in. of slump is mostly adequate. For contractors new to slipforming, we can provide our input and review the intended concrete mix and give our recommendations.

Learn More

8 ESSENTIAL QUALITY REQUIREMENTS OF PUMPED CONCRETE

Mar 21, 2016 · Concrete should be sampled at both ends of the pumpline to determine what, if any, changes in the slump, air content, and other concrete properties occur during pumping. However, the quality of the concrete being placed in the structure can only be …

Learn More

Best Mix for Pumped Concrete | JLC Online

Mix Design and Pumped Concrete - Civil Engineering Portal

Learn More

Types of Concrete Slump - Civil Engineering

The concrete slump can be classified according to the nature of concrete fall. There are 3 types of the slump. These are: True slump: In a true slump concrete just subsides shortly and more or less maintain the mould shape. This type of slump is most desirable. …

Learn More

What is concrete pump mix? | Concrete PUMPING CUTTING

Pumping equipment consists of pumps which are of three types: Piston type concrete pump; Pneumatic type concrete pump; Squeeze pressure type concrete pump; Other accessories are rigid pipelines, flexible hose and couplings etc.

Learn More

Mix Design for Pumpable Concrete | Materials | Concrete

The workability of pumped concrete in general have a average slump of between 50 mm and 100 mm. A concrete of less than 50 mm slumps are impractical for pumping, and slump above 125 mm should be avoided. In mixtures with high slump, the aggregate will segregate from the mortar and paste and may cause blocking in the pump lines.

Learn More

Mix Design for Pumped Concrete with PPC, OPC, OPC+Flyash

S1 slumps are most likely to be used for kerb and pipework bedding because it's quite a dry concrete mix. This is sometimes referred to as "semi-dry". S2 slumps are used for simple strip footings and cast in-situ hard-standing slabs or when using a wheel barrow to move the concrete.

Learn More

Concrete Slump Test Procedure, Applications & Types of …

Mix Design and Pumped Concrete - Civil Engineering Portal

Learn More

Mix Design for Pumpable Concrete | Materials | Concrete

Design a mix for pumpable concrete from the following data: 1. The max. size of coarse aggregate = 20 mm. 2. The fine aggregate passes through the 300 micron or 0.3 mm = 19% . 3. Slump of concrete = 75 to 100 mm . Procedure: The proportions for 75-100 mm slump will be taken as given in table 20.52. From the table 20.52, Water = 190 kg or litres

Learn More

The Different Types of Concrete Pumps – Cedar Park Concrete

Nov 08, 2021 · Stationary pumps are known for pouring concrete at a slower speed than other types of pump. So it's recommended where the demand for a smaller volume of concrete is required for a construction project. Specialised Usage Pump. Specialised usage pumps are one of the different types of concrete pumps that are readily available.

Learn More

Guide to Placing Concrete by Pumping Methods Guide to

4.2.2 Ball valve concrete pumps (Fig. 4.2.2) —This type of pump uses steel balls and mating seats to control the ow of concrete from the hopper into the pumping cylinder and

Learn More

Guide To Concrete Workability | Concrete Slump | Concrete2you

Mar 01, 2010 · Generally speaking, the maximum slump for a pumped mix is about 6 inches. The ideal concrete mix for pumping typically contains air-entraining agents, a little extra sand (compared with a standard concrete mix), often some fly ash, and a well-graded aggregate blend. To make the concrete easier to pump and place as it comes out of the hose, many batch plants also add water-reducing …

Learn More

Concrete Techniques And Applications For Pumping

Aug 02, 2017 · This means checking that your pumping concrete techniques and applications are working hard for you, instead of making you do extra work. Applications include all types of sawing cutting and drilling work afterwords. Once the concrete is laid please ensure that that concrete is cut, with a saw cutting machine.

Learn More

Mix Design and Pumped Concrete

Slump in mm; S1 Dry (Kerb backing, dry fill and sloping slabs etc.) 10 – 40: S2 Standard (Foundations, Slabs and other general structures) 50 – 90: S3 Wet (Foundations, slabs, Pumping concrete) 100 – 150: S4 Very Wet (Foundations, slabs, Pumping and Piling concretes) 160-210: S5 Self Levelling (Foundations, slabs, Pumping and Piling concretes)

Learn More

CONCRETE - Boral

a) Dry slump concretes (20 to 50mm) giving very low shrinkages due to reduced water content, but are difficult to work in their plastic state. b) Normal slump concretes (60 to 100mm) giving suitable workability for general purpose applications. c) Medium slump concrete (120mm to 160mm slump) for improved pumpability (130 plus metres high)